Quantcast

Improving Pulmonary Embolism Detection

March 23, 2012

(Ivanhoe Newswire) — Researchers have discovered an alternative method of detecting pulmonary embolism that is changing the game.

Pulmonary embolisms occur when a blood clot — usually from the leg — travels to the lung and blocks the pulmonary artery or one of its main branches. CT angiography is the gold standard for diagnosis, but it exposes patients to ionizing radiation and iodinated contrast agent, which carries a risk of allergic reactions and kidney damage in some patients. However, a new research shows that by adding two magnetic resonance imaging (MRI) sequences to a MR angiography technique can significantly improve pulmonary embolism detection.

MRI has been used for pulmonary embolism detection in pregnant women and patients whose kidneys may be harmed by CT angiography contrast agents. However, the Prospective Investigation of Pulmonary Embolism Diagnosis III (PIOPED III) study, a major multicenter trial, found that centers had difficulty obtaining adequate quality MR pulmonary angiography (MRPA) for suspected pulmonary embolism.

“MRI is developing much faster than CT,” Diego R. Martin, M.D., Ph.D., head of the Department of Radiology at the University of Arizona College of Medicine in Tucson was quoted saying. “The images we’re getting are already significantly better than they were a year ago. There is no doubt that in the future we will be able to offer a non-radiation-based alternative to CT for the diagnosis of pulmonary embolism.”

In the new study, the research team assessed the impact of two additional MRI sequences on MRPA’s accuracy. The two techniques–contrast-enhanced volumetric interpolated breath-hold examination (VIBE) and non-contrast true fast imaging with steady-state precession (true FISP)–complement MRPA, according to Dr. Martin.

The addition of VIBE provides a gray scale that enables readers to distinguish between the clot, or thrombus, and the lung, which both appear dark on MRPA.

“Also, VIBE is not time sensitive,” Dr. Martin was quoted saying. “If the patient coughs, you can do it again. You don’t have that option with MRPA.”

The true FISP test does not require contrast agent or a breath hold, an important consideration for embolism patients who often cannot hold their breath long enough for image acquisition on MRPA.

When Dr. Martin and colleagues studied the three techniques on 22 patients with CTA diagnosis of pulmonary embolism, they found a sensitivity of 55 percent, 67 percent and 73 percent for MRPA, true FISP and VIBE, respectively. Combining all three MRI sequences improved the overall detection rate to 84 percent. Specificity was 100 percent for all detection methods except for MRPA, which demonstrated one false positive.

Dr. Martin hopes his findings stimulate discussion of a new, redesigned PIOPED study.

“PIOPED III did not answer the question of whether or not MRI is a useful alternative to CT, because it didn’t use all the tools available,” he said.

The MRI sequences used in the study are offered on all the major vendor systems, according to Dr. Martin, with the entire three-sequence protocol taking only 15 minutes to set up and perform.

SOURCE: Radiology, March 2012




comments powered by Disqus