Bomb-Proof Thermometer Withstands Explosions
Posted on: Wednesday, 8 October 2008, 16:39 CDT
Scientists at the UK's National Physical Laboratory (NPL) in Teddington have designed a high-speed thermometer that can measure the temperature inside explosions without being damaged in the impact.
The shockwave, heat, soot and debris from an explosion can damage thermometers. Conventional thermocouples do not react quickly enough to capture the information. This makes modeling the interaction of an explosion with its environment problematic – as temperature is essential in any calculations.
NPL scientists have now designed a reusable bomb-proof thermometer to understand the physical and chemical processes that occur during the detonation and expansion phases of an explosion. It is an optical fiber 400 microns (0.4 mm) across, protected from the blast by a sand-packed steel tube with one open end.
The thermometer detects thermal radiation at four different wavelengths, collecting more information about the thermal physics of the explosion than could be obtained from any one wavelength alone. The optical fiber probe collects thermal radiation, which is transmitted over a suitable safe distance to the main instrumentation.
To measure the temperature of the fireball, the thermometer was first calibrated up to 3000 K (2727 °C). This made it possible to convert the measured thermal radiation signals into temperatures. The thermometer can take 50,000 measurements per second, producing a detailed profile of temperature changes during a split-second detonation.
After a successful simple field trial NPL now hopes to examine much larger explosions. The findings will help to fine tune predictive models on many different explosion parameters.
NPL lead scientist, Gavin Sutton said:
"We produced a working prototype thermometer after some successful field trials and hope to measure the temperature of full-scale explosions in the near future. The lab tests involved temperatures of over 3000 kelvin and the only damage done was a small amount soot off the end of the optic fiber – which we easily removed with alcohol and a cotton bud."
---
Image Caption: The detonation of a small pyrotechnic charge in the NPL facility. A radiation pyrometer on the left side of the image observes the event. Credit: NPL
---
On the Net:
Related Articles
- AFSI Certified to Supply Measurement Quality Jumpers
- TI Introduces Smallest Local Digital Temperature Sensor for Thermal Management and Thermal Protection
- TI Introduces +/-1C Remote and Local Temperature Sensor for Thermal System Management
- 16 Killed by Female Bomber in Iraq
- Blast at Serb explosives plant kills four
- Accuracy of Lake and Stream Temperatures Estimated From Thermal Infrared Images1
- Explosive Radiations and the Reliability of Molecular Clocks: Island Endemic Radiations As a Test Case
- Temperature Calibration Of Efpi Fiber Optic Strain Sensors
- NIST researchers complete international intercomparison of optical fiber power measurements
- Asian Airports to Implement SARS Measures
User Comments (0)


RSS Feeds